Turn off circuit breaker
shut off cold water entering the tank using shutoff valve
connect hose to spout at bottom and run hose outside
turn a hot water faucet on somewhere in the house. This lets air into the tank
use screwdriver to open valve at hose connection
let drain. Could take awhile
to remove sediment turn cold water on for 20 seconds then off. Let drain. Repeat 2-3 times
close valve with screwdriver and disconnect hose
slowly turn cold water back on. Make sure hot water faucet is still open
let fill then turn breaker back on